⚖️ New in v3.3+
Calibration is now done directly on the device! Just update your firmware to v3.3 and you'll find a new "Calibration" menu item. Simply pour a known volume and the factor recalculates automatically. The calculator below is only for older versions.
More in the guide →
Calibration is now done directly on the device! Just update your firmware to v3.3 and you'll find a new "Calibration" menu item. Simply pour a known volume and the factor recalculates automatically. The calculator below is only for older versions.
More in the guide →
⚙️ TURBINE CALIBRATION FACTOR CALCULATOR
ℹ️ Calibration guide:
In the "measured" field, enter the value displayed on the RoboPípa display after pouring glasses of various volumes. The calibration factor used during calibration must be entered correctly (version 1.0 - 210, higher versions use 168). If you don't want to calibrate, you can leave the middle value at 168. The more glasses you measure, the more accurate your RoboPípa will be. I recommend the following 3. Note the average value and enter it as the new factor via WiFi or BT interface.
In the "measured" field, enter the value displayed on the RoboPípa display after pouring glasses of various volumes. The calibration factor used during calibration must be entered correctly (version 1.0 - 210, higher versions use 168). If you don't want to calibrate, you can leave the middle value at 168. The more glasses you measure, the more accurate your RoboPípa will be. I recommend the following 3. Note the average value and enter it as the new factor via WiFi or BT interface.
| Volume | Measured | Factor |
|---|---|---|
| Factor used for measurement | ||
| 0,3 l | ||
| 0,4 l | ||
| 0,5 l | ||
| Average |
💡 Tip:
Enter your current calibration factor (found in RoboPípa settings), pour 3 different volumes and measure them. Enter the measured values and the average will give you the new optimal calibration factor.
Enter your current calibration factor (found in RoboPípa settings), pour 3 different volumes and measure them. Enter the measured values and the average will give you the new optimal calibration factor.
⚙️ OVAL WHEELS CALIBRATION FACTOR CALCULATOR
ℹ️ Calibration guide:
In the "measured" field, enter the value displayed on the RoboPípa display after pouring glasses of various volumes. The calibration factor used during calibration must be entered correctly (default value 580). Note the average value and enter it as the new factor via WiFi or BT interface.
In the "measured" field, enter the value displayed on the RoboPípa display after pouring glasses of various volumes. The calibration factor used during calibration must be entered correctly (default value 580). Note the average value and enter it as the new factor via WiFi or BT interface.
| Volume | Measured | Factor |
|---|---|---|
| Factor used for measurement | ||
| 0,3 l | ||
| 0,4 l | ||
| 0,5 l | ||
| Average |
💡 Tip:
Enter your current oval wheels calibration factor (default 580), pour 3 different volumes and measure them. Enter the measured values and the average will give you the new optimal calibration factor.
Enter your current oval wheels calibration factor (default 580), pour 3 different volumes and measure them. Enter the measured values and the average will give you the new optimal calibration factor.